IEC > Webstore > Search > Register > Check out > Payment > Order confirmation

Publication detail

 
Reference IEC 60664-4 ed2.0 withdrawn corrigendum

no
preview
Title Versión Oficial en Español - Coordinación de aislamiento de los equipos en los sistemas (redes) de baja tensión. Parte 4: Consideración de los esfuerzos de tensión a alta frecuencia
Publication date 2005-09-15
Format, price
(Swiss francs)
and language
280.- 135 pages
280.- 1414 Kb
 
Abstract Deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for basic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz. This part of IEC 60664 can only be used together with IEC 60664-1 or with IEC 60664-5 (in this standard called Part 1 or Part 5). By using Part 1 or Part 5 together with this part the frequency limit of Part 1 or Part 5 is extended to frequencies higher than 30 kHz. This part also applies to Part 3 for frequencies greater than 30 kHz and protection of type 1. For type 2 protection this question is under consideration. Applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 000 V. Specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. lt includes methods of electric testing with respect to insulation coordination. The minimum clearances specified in this part do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee. This part does not deal with distances - through liquid insulation, - through gases other than air, - through compressed air. The object of this standard is to guide technical committees responsible for different equipment in order to rationalise their requirements so that insulation coordination is achieved when specifying clearances in air, creepage distances and solid insulation for equipment. The major changes made during the revision of IEC 60664-4 were the following: - inclusion of more recent information about the withstand characteristics of insulation at high-frequency voltage stress (see Annexes A, B and C); - inclusion of requirements for the dimensioning of clearances at high-frequency voltage stress (see Clause 4); - inclusion of requirements for the dimensioning of creepage distances at high-frequency voltage stress (see Clause 5); - inclusion of requirements for the dimensioning of solid insulation at high-frequency voltage stress (see Clause 6); - inclusion of diagrams to provide guidance on dimensioning with respect to high-frequency voltage stress (see Annex F); specification of tests with respect to high-frequency voltage stress (see Clause 7). - inclusion of test circuits for high-frequency voltage withstand testing and partial discharge testing (see Annex D.1 and D.2.1); - inclusion of design criteria for partial discharge test circuits at high-frequency voltage (see Annex D.2.2); - inclusion of criteria for dealing with non sinusoidal voltage stress (see Clause 8 and Annex E). Has the status of a basic safety publication in accordance with IEC Guide 104.
Technical Committee 109 - Insulation co-ordination for low-voltage equipment  RSS
ICS Codes
29.080.30 Insulation systems
 
Replaced by
Stability date 2020
 
Work in progress
ProjectStage codeForecast publication date
No project under development--


Search

>> Advanced search

Quick access by ref. number



Basket

Your basket is empty
Your country is :
Your TVA is : You must login...

Payment

Accepted credit cards:
Prices in CHF (Swiss francs)
Request a pro forma to pay by bank transfer or cheque
Learn how to share your publications with your colleagues, using networking options
Prices in CHF (Swiss francs)
We accept the following credit cards:
To pay by bank transfer: request a pro forma
If you purchase regularly through the IEC Webstore you can open a corporate account

Just Published

>> Published in the last 30 days

Bestsellers

  1. IEC 60601-1-2 Ed. 4.0
  2. IEC 60825-1 Ed. 3.0
  3. IEC 60529 Ed. 2.2
  4. IEC 61000-4-5 Ed. 3.0
  5. IEC 60068-2-30 Ed. 3.0
  6. IEC 60079-0 Ed. 6.0
  7. IEC 60811-501 Ed. 1.0
  8. IEC 62133 Ed. 2.0
  9. IEC 60950-1 Ed. 2.2
  10. IEC 61000-4-2 Ed. 2.0