Publication detail

 
Reference IEC 60909-3 ed3.0 withdrawn corrigendum

no
preview
Title Versión Oficial En español - Corrientes de cortocircuito en sistemas trifásicos de corriente alterna. Parte 3: Corrientes durante dos cortocircuitos monofásicos a tierra simultáneos y separados y corrientes parciales de cortocircuito circulando a través de tierra.
Publication date 2009-03-09
Format, price
(Swiss francs)
and language
250.- 117 pages
250.- 2350 Kb
 
Abstract IEC 60909-3:2009 specifies procedures for calculation of the prospective short-circuit currents with an unbalanced short circuit in high-voltage three-phase a.c. systems operating at nominal frequency 50 Hz or 60 Hz, i. e.:
- currents during two separate simultaneous line-to-earth short circuits in isolated neutral or resonant earthed neutral systems;
- partial short-circuit currents flowing through earth in case of single line-to-earth short circuit in solidly earthed or low-impedance earthed neutral systems.
The currents calculated by these procedures are used when determining induced voltages or touch or step voltages and rise of earth potential at a station (power station or substation) and the towers of overhead lines. Procedures are given for the calculation of reduction factors of overhead lines with one or two earth wires. This edition constitutes a technical revision. The main changes with respect to the previous edition are:
- New procedures are introduced for the calculation of reduction factors of the sheaths or shields and in addition the current distribution through earth and the sheaths or shields of three-core cables or of three single-core cables with metallic non-magnetic sheaths or shields earthed at both ends;
- The information for the calculation of the reduction factor of overhead lines with earth wires are corrected and given in the new Clause 7;
- A new Clause 8 is introduced for the calculation of current distribution and reduction factor of three-core cables with metallic sheath or shield earthed at both ends;
- The new Annexes C and D provide examples for the calculation of reduction factors and current distribution in case of cables with metallic sheath and shield earthed at both ends.

This publication is to be read in conjunction with IE C 60909-0:2001.

NEW! IEC 60909-3:2009 is also available as IEC Standards+ 60909-3:2009 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
Technical Committee 73 - Short-circuit currents  RSS
ICS Codes
17.220.01 Electricity. Magnetism. General aspects
*Including electromagnetism

29.240.20 Power transmission and distribution lines
 
Replaced by
Stability date 2016
 
Work in progress
ProjectStage codeForecast publication date
No project under development--


Search

>> Advanced search

Quick access by ref. number



Basket

Your basket is empty
Your country is :
Your TVA is : You must login...

Payment

Accepted credit cards:
Prices in CHF (Swiss francs)
Request a pro forma to pay by bank transfer or cheque
Learn how to share your publications with your colleagues, using networking options
Prices in CHF (Swiss francs)
We accept the following credit cards:
To pay by bank transfer: request a pro forma
If you purchase regularly through the IEC Webstore you can open a corporate account

Just Published

>> Published in the last 30 days

Bestsellers

  1. IEC 60601-1-2 Ed. 4.0
  2. IEC 60825-1 Ed. 3.0
  3. IEC 61000-4-5 Ed. 3.0
  4. IEC 60079-1 Ed. 7.0
  5. IEC 60598-1 Ed. 8.0
  6. IEC 61000-3-2 Ed. 4.0
  7. IEC 60034-2-1 Ed. 2.0
  8. IEC 60068-2-30 Ed. 3.0
  9. IEC 60601-1 Ed. 3.1
  10. IEC 61000-4-6 Ed. 4.0