IEC > Webstore > Search > Register > Check out > Payment > Order confirmation

Publication detail

 
Reference IEC 62271-106 ed1.0 withdrawn corrigendum

no
preview
Title Versión Oficial En español - Aparamenta de alta tensión. Parte 106: Contactores, controladores y arrancadores de motor con contactores, de corriente alterna.
Publication date 2011-08-19
Format, price
(Swiss francs)
and language
290.- 167 pages
290.- 1251 Kb
 
Abstract IEC 62271-106:2011 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in single-phase systems are subject to agreement between manufacturer and user. This standard cancels and replaces the second edition of IEC 60470 published in 1999. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60470:1999:
- Scope and object: The voltage range covered by the standard was expanded from 12 kV to 24 kV. Overload relay calibration and testing is not covered by this standard.
- 3 Terms and definitions: Added definitions for capacitor switching classes.
- 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values.
- 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in the testing section).
- 4.112 Rated capacitive switching currents: Added capacitor switching current ratings.
- 5.101 Protective relays: Removed the requirements for overload relays. This section is obsolete since there are only a few MV starters fitted with thermal overload relays and electronic relays have their own standards.
- 6.2.5 Application of the test voltage and test conditions (former 6.2.2 b)): Changed wording of requirement for impulse across the open gap of vacuum contactors.
- 6.4.2 Auxiliary circuits: The requirement for resistance checks of auxiliary circuits was deleted.
- 6.5.5.104 Temperature rise of the auto transformer or reactor for two step auto transformer or reactor starters: Reworded to transfer ratings to subclause 4.109.2.
- 6.102.9 Condition following making and breaking tests: Gave specific direction as to what the tolerance should be based on where the resistance was to be checked.
- 6.104 Short-circuit current making and breaking tests: Clarified test conditions for short-circuit testing.
- 6.109 Capacitive current switching tests: Added capacitive current switching tests.
- Annex B: Added Table B.1 - Tolerances on test quantities for type test.
Technical Committee 17A - High-voltage switchgear and controlgear  RSS
ICS Codes
29.130.10 High voltage switchgear and controlgear
*Including enclosed switchgear and controlgear
 
Replaced by
Stability date 2018
 
Work in progress
ProjectStage codeForecast publication date
No project under development--


Search

>> Advanced search

Quick access by ref. number



Basket

Your basket is empty
Your country is :
Your TVA is : You must login...

Payment

Accepted credit cards:
Prices in CHF (Swiss francs)
Request a pro forma to pay by bank transfer or cheque
Learn how to share your publications with your colleagues, using networking options
Prices in CHF (Swiss francs)
We accept the following credit cards:
To pay by bank transfer: request a pro forma
If you purchase regularly through the IEC Webstore you can open a corporate account

Just Published

>> Published in the last 30 days

Bestsellers

  1. IEC 60601-1-2 Ed. 4.0
  2. IEC 60529 Ed. 2.2
  3. IEC 60825-1 Ed. 3.0
  4. IEC 61000-4-5 Ed. 3.0
  5. IEC 62682 Ed. 1.0
  6. IEC 60079-0 Ed. 6.0
  7. IEC 61000-3-2 Ed. 4.0
  8. IEC 61010-1 Ed. 3.0
  9. IEC 61439-1 Ed. 2.0
  10. IEC 61439-2 Ed. 2.0