Publication detail

 
Reference IEC 60627 ed3.0 withdrawn corrigendum
> preview
Title Diagnostic X-ray imaging equipment - Characteristics of general purpose and mammographic anti-scatter grids
Publication date 2013-07-09
Format, price
(Swiss francs)
and language
190.- 69 pages
190.- 1381 Kb
 
Abstract IEC 60627:2013 is applicable to anti-scatter grids used in medical diagnostic X-ray imaging equipment. Anti-Scatter Grids are used to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern. This International Standard specifies the definitions, determination and indication of characteristics of anti-scatter grids. In this standard only linear grids are considered. Since at present only focused grids are used in mammography, this standard is restricted to focused grids where mammographic anti-scatter grids are concerned. This standard is not intended to be applied for acceptance tests. This standard does not cover the homogeneity of performance over the area of a grid. This standard is intended to be applied for the determination of the characteristics of anti-scatter grids under test conditions. These conditions are not usually available at the site of the responsible organization. This third edition cancels and replaces the second edition published in 2001, and constitutes a technical revision. In this revision calcium tungstate phosphor fluorescent screens, which are no longer available, have been replaced by gadolinium oxysulphide (GOS) fluorescent screens. Further, a new quality parameter is introduced: the Image Improvement Factor or Q-factor, which better describes the properties of the anti-scatter grid, especially for digital detector applications. Further differences between this third edition and the previous second edition are:
- new instrumentation is prescribed for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation, because fluorescent screens made of calcium tungstate phosphors are outdated and are no longer available;
- the definition of the phantom used for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation is modified and references to IEC 61267 are omitted;
- and the radiation conditions used for the measurements have been adapted and are now the RQR and RQR-M conditions specified in IEC 61267:2005.
Technical Committee 62B - Diagnostic imaging equipment  RSS
ICS Codes
11.040.50 Radiographic equipment
*Including radiographic diagnostic and therapy equipment
*Dental, medical and industrial radiographic films, see 37.040.25
 
Replaced by
Stability date 2018
 
Work in progress
ProjectStage codeForecast publication date
No project under development--


Search

>> Advanced search

Quick access by ref. number



Basket

Your basket is empty
Your country is :
Your TVA is : You must login...

Payment

Accepted credit cards:
Prices in CHF (Swiss francs)
Request a pro forma to pay by bank transfer or cheque
Learn how to share your publications with your colleagues, using networking options
Prices in CHF (Swiss francs)
We accept the following credit cards:
To pay by bank transfer: request a pro forma
If you purchase regularly through the IEC Webstore you can open a corporate account

Just Published

>> Published in the last 30 days

Bestsellers

  1. IEC 60601-1-2 Ed. 4.0
  2. IEC 60825-1 Ed. 3.0
  3. IEC 61010-1 Ed. 3.0
  4. IEC 60529 Ed. 2.2
  5. IEC 62682 Ed. 1.0
  6. IEC 61000-4-5 Ed. 3.0
  7. IEC 61439-1 Ed. 2.0
  8. IEC 60079-0 Ed. 6.0
  9. IEC 61000-3-2 Ed. 4.0
  10. IEC 61439-2 Ed. 2.0