IEC 60695-11-10 Revised
IEC 60695-11-10:1999
Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
Specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically or horizontally oriented specimens made from plastic and other non-metallic materials, exposed to a small-flame ignition source of 50 W nominal power. These test methods determine the linear burning rate and the afterflame/afterglow times, as well as the damaged length of specimens. Applicable to solid and cellular materials that have an apparent density of not less than 250 kg/m3, determined in accordance with ISO 845. They do not apply to materials that shrink away from applied flame without igniting; ISO 9773 should be used for thin flexible materials. The test methods described provide classification systems which may be used for quality assurance, or the pre-selection of component materials of products. May be used for the pre-selection of a material, providing positive results are obtained at a thickness equal to the smallest thickness used in the application. Has the status of a basic safety publication in accordance with Guide 104.
CHFÂ 155.-
A more recent version of this publication exists:
IEC 60695-11-10:2013/COR1:2014
Technical committee
TC 89 Fire hazard testingCategory
Basic SafetyPublication type | International Standard |
Publication date | 1999-03-31 |
Edition | 1.0 |
ICS | 13.220.40 29.020 |
Withdrawal date | 2013-05-21 |
ISBN number | 2831846269 |
Pages | 45 |
File size | 193.58 KB |