IEC 61290-1-1 Revised
IEC 61290-1-1:1998
Optical fibre amplifiers - Basic specification - Part 1-1: Test methods for gain parameters - Optical spectrum analyzer
Applies to optical fibre amplifiers using active fibres, containing rare-earth dopants, presently commercially available. Establishes uniform requirements for accurate and reliable measurements, by means of the optical spectrum analyzer test method, of the following OFA parameters:
- small-signal gain;
- reverse small-signal gain;
- maximum small-signal gain;
- maximum small-signal gain wavelength;
- maximum small-signal gain variation with temperature;
- small-signal gain wavelength band;
- small-signal gain wavelength variation;
- small signal gain stability;
- polarization-dependent gain variation.
- small-signal gain;
- reverse small-signal gain;
- maximum small-signal gain;
- maximum small-signal gain wavelength;
- maximum small-signal gain variation with temperature;
- small-signal gain wavelength band;
- small-signal gain wavelength variation;
- small signal gain stability;
- polarization-dependent gain variation.
CHFÂ 80.-
A more recent version of this publication exists:
IEC 61290-1-1:2020 RLV
Technical committee
TC 86/SC 86C Fibre optic systems, sensing and active devicesKeywords
Fibre opticsPublication type | International Standard |
Publication date | 1998-05-08 |
Edition | 1.0 |
ICS | 33.180.30 |
Withdrawal date | 2006-08-21 |
ISBN number | 2831843642 |
Pages | 27 |
File size | 144.69 KB |