Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization;
– located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation;
– located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation;
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurization and artificial ventilation.
The term "room" used in this document includes single rooms, multiple rooms, a complete building or a room contained within a building. A room is intended to facilitate the entry of personnel and includes inlet and outlet ducts. An acoustic hood and other like enclosures designed to permit the entry of personnel can be considered as a room.
This document also includes requirements related safety devices and controls necessary to ensure that artificial ventilation, purging and pressurization is established and maintained.
A room assembled or constructed on site, can be either on land or off-shore. The room is primarily intended for installation by an end-user but could be constructed and assessed at a manufacturer’s facility, where the final construction such as ducting can be completed on site.
This document does not specify the methods that may be required to ensure adequate air quality for personnel with regard to toxicity and temperature within the room. National or other regulations and requirements may exist to ensure the safety of personnel in this regard.
This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p";
b) addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv";
c) definition of the differences between pressurization and artificial ventilation types of protection;
d) removal of protection of rooms with an inert gas or a flammable gas from the scope of this document;
e) addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.
BASE PUBLICATION
  CHF 260.-

Technical committee

TC 31/SC 31J Classification of hazardous areas and installation requirements

Keywords

Pressurized room - Artificially ventilated room
Publication typeInternational Standard
Publication date2017-05-22
Edition2.0
ICS

29.260.20

Stability date2026
ISBN number9782832262047
Pages35
File size1.17 MB
EditionDatePublicationEditionStatus
  • Ensure healthy lives and promote well-being for all

  • Ensure availability and sustainable management of water and sanitation for all

  • Ensure access to affordable, reliable, sustainable and modern energy for all

  • Promote inclusive and sustainable economic growth, full and productive employment and decent work for all

  • Build resilient infrastructure, promote inclusive and sustainable industrialization and foster innovation

  • Reduce inequality within and among countries

  • Make cities and human settlements inclusive, safe, resilient and sustainable

  • Ensure sustainable consumption and production patterns

  • Conserve and sustainably use ocean, sea and marine resources

  • Promote sustainable use of terrestrial ecosystems, halt and reverse land degradation and biodiversity loss

See more

Related publications

Related test report forms