IEC 61508-6
IEC 61508-6:2010
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
Looking for deeper insights? Check out IEC 61508:2010 CMV, which includes commented versions of Parts 1 to 7 of IEC 61508. These commented versions highlight the changes made from previous editions and provide explanations from a world-leading expert on the reasons behind the most significant changes.
IEC 61508-6:2010 contains information and guidelines on IEC 61508-2 and IEC 61508 3. Annex A gives a brief overview of the requirements of IEC 61508-2 and IEC 61508-3 and sets out the functional steps in their application. Annex B gives an example technique for calculating the probabilities of hardware failure and should be read in conjunction with 7.4.3 and Annex C of IEC 61508-2 and Annex D. Annex C gives a worked example of calculating diagnostic coverage and should be read in conjunction with Annex C of IEC 61508-2. Annex D gives a methodology for quantifying the effect of hardware-related common cause failures on the probability of failure. Annex E gives worked examples of the application of the software safety integrity tables specified in Annex A of IEC 61508-3 for safety integrity levels 2 and 3. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. It has been subject to a thorough review and incorporates many comments received at the various revision stages.
This publication is of high relevance for Smart Grid.
IEC 61508-6:2010 contains information and guidelines on IEC 61508-2 and IEC 61508 3. Annex A gives a brief overview of the requirements of IEC 61508-2 and IEC 61508-3 and sets out the functional steps in their application. Annex B gives an example technique for calculating the probabilities of hardware failure and should be read in conjunction with 7.4.3 and Annex C of IEC 61508-2 and Annex D. Annex C gives a worked example of calculating diagnostic coverage and should be read in conjunction with Annex C of IEC 61508-2. Annex D gives a methodology for quantifying the effect of hardware-related common cause failures on the probability of failure. Annex E gives worked examples of the application of the software safety integrity tables specified in Annex A of IEC 61508-3 for safety integrity levels 2 and 3. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. It has been subject to a thorough review and incorporates many comments received at the various revision stages.
This publication is of high relevance for Smart Grid.
CHFÂ 385.-
Technical committee
TC 65/SC 65A System aspectsCategory
Horizontal standard - Safety - Basic SafetyKeywords
Functional safety - Smart city| Publication type | International Standard |
| Publication date | 2010-04-30 |
| Edition | 2.0 |
| ICS | 25.040.40 |
| Stability date | 2027 |
| ISBN number | 9782889105298 |
| Pages | 237 |
| File size | 2.81 MB |