Share by email

IEC 61788-3

IEC 61788-3:2006
Superconductivity - Part 3: Critical current measurement - DC critical current of Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors
This part of IEC 61788 covers a test method for the determination of the dc critical current of short and straight Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors that have a monolithic structure and a shape of round wire or flat or square tape containing mono- or multicores of oxides.

This method is intended for use with superconductors that have critical currents less than 500 A and n-values larger than 5. The test is carried out with and without an applying external magnetic field. For all tests in a magnetic field, the magnetic field is perpendicular to the length of the specimen. In the test of a tape specimen in a magnetic field, the magnetic field is parallel or perpendicular to the wider tape surface (or one surface if square). The test specimen is immersed either in a liquid helium bath or a liquid nitrogen bath during testing. Deviations from this test method that are allowed for routine tests and other specific restrictions are given in this standard.
BASE PUBLICATION
English
  CHF 155.-

Technical committee

TC 90 Superconductivity
Publication typeInternational Standard
Publication date2006-04-27
Edition2.0
ICS

17.220.20

29.050

Stability date2025
ISBN number2831886147
Pages23
File size347.54 KB
EditionDatePublicationEditionStatus
  • Ensure healthy lives and promote well-being for all

  • Ensure access to affordable, reliable, sustainable and modern energy for all

  • Build resilient infrastructure, promote inclusive and sustainable industrialization and foster innovation

  • Take urgent action to combat climate change and its impacts

See more

Related publications