Radiation protection instrumentation - Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation
IEC 62387:2020 applies to all kinds of passive dosimetry systems that are used for measuring:
- the personal dose equivalent Hp(10) (for individual whole body monitoring),
- the personal dose equivalent Hp(3) (for individual eye lens monitoring),
- the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring),
- the ambient dose equivalent H*(10) (for workplace and environmental monitoring),
- the directional dose equivalent H'(3) (for workplace and environmental monitoring), or
- the directional dose equivalent H'(0,07) (for workplace and environmental monitoring).
This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
- the personal dose equivalent Hp(10) (for individual whole body monitoring),
- the personal dose equivalent Hp(3) (for individual eye lens monitoring),
- the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring),
- the ambient dose equivalent H*(10) (for workplace and environmental monitoring),
- the directional dose equivalent H'(3) (for workplace and environmental monitoring), or
- the directional dose equivalent H'(0,07) (for workplace and environmental monitoring).
This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
CHFÂ 365.-
Redline version
All the changes between the new edition and previous edition of the publication are highlighted with track changes mode.
DiscoverTechnical committee
TC 45/SC 45B Radiation protection instrumentationPublication type | International Standard |
Publication date | 2020-01-31 |
Edition | 2.0 |
ICS | 13.280 |
Stability date | 2027 |
ISBN number | 9782832276969 |
Pages | 180 |
File size | 3.47 MB |
Promote inclusive and sustainable economic growth, full and productive employment and decent work for all