IEC Technical Specification 62607-9-2
IEC TS 62607-9-2:2024
Nanomanufacturing - Key control characteristics - Part 9-2: Nanomagnetic products - Magnetic field distribution: Magneto-optical indicator film technique
IEC TS 62607-9-2:2024, which is a Technical Specification, establishes a standardized method to determine the key control characteristic
• magnetic field distribution
of nanomagnetic materials, structures and devices by the
• magneto-optical indicator film technique.
The magnetic field distribution is derived by utilizing a magneto optical indicator film, which is a thin film of magneto-optic material that is placed on the surface of an object exhibiting a spatially varying magnetic field distribution. The Faraday effect is then employed to measure the magnetic field strength by analysing the rotation of the polarization plane of light passing through the magneto-optic film.
The method is applicable for measuring the stray field distribution of flat nanomagnetic materials, structures and devices.
- The method can especially be used to perform fast quantitative measurements of stray field distributions at the surface of an object.
- The magneto-optic indicator film technique (MOIF) is a fast, non-destructive method, making it an attractive option for materials analysis and testing in the industry.
- MOIF measurements can be done without any sample preparation and do not rely on specific surface properties of the object. It can be applied to the characterization of rough samples as well as of samples with non-magnetic cover layers.
- MOIF can quantitatively measure magnetic field distributions:
• with a one-shot measurement which typically takes a few seconds
• over areas of several square centimetres (over diameters of up to 15 cm with special techniques)
• in a field range from 1 mT to more than 100 mT
• with down to 1 µm spatial resolution
- Although techniques with nano-scale resolution are suitable for analysing the details of magnetic field structure, their ability to characterize larger areas is limited by their scanning area. Therefore, the MOIF technique is an indispensable complementary method that can offer a more comprehensive understanding of material properties.
This document focuses on the calibration procedures, calibrated measurement process, and evaluation of measurement uncertainty to ensure the traceability of quantitative magnetic field measurements obtained through the magneto-optic indicator film technique.
• magnetic field distribution
of nanomagnetic materials, structures and devices by the
• magneto-optical indicator film technique.
The magnetic field distribution is derived by utilizing a magneto optical indicator film, which is a thin film of magneto-optic material that is placed on the surface of an object exhibiting a spatially varying magnetic field distribution. The Faraday effect is then employed to measure the magnetic field strength by analysing the rotation of the polarization plane of light passing through the magneto-optic film.
The method is applicable for measuring the stray field distribution of flat nanomagnetic materials, structures and devices.
- The method can especially be used to perform fast quantitative measurements of stray field distributions at the surface of an object.
- The magneto-optic indicator film technique (MOIF) is a fast, non-destructive method, making it an attractive option for materials analysis and testing in the industry.
- MOIF measurements can be done without any sample preparation and do not rely on specific surface properties of the object. It can be applied to the characterization of rough samples as well as of samples with non-magnetic cover layers.
- MOIF can quantitatively measure magnetic field distributions:
• with a one-shot measurement which typically takes a few seconds
• over areas of several square centimetres (over diameters of up to 15 cm with special techniques)
• in a field range from 1 mT to more than 100 mT
• with down to 1 µm spatial resolution
- Although techniques with nano-scale resolution are suitable for analysing the details of magnetic field structure, their ability to characterize larger areas is limited by their scanning area. Therefore, the MOIF technique is an indispensable complementary method that can offer a more comprehensive understanding of material properties.
This document focuses on the calibration procedures, calibrated measurement process, and evaluation of measurement uncertainty to ensure the traceability of quantitative magnetic field measurements obtained through the magneto-optic indicator film technique.
CHF 345.-
Technical committee
TC 113 Nanotechnology for electrotechnical products and systemsPublication type | Technical Specification |
Publication date | 2024-07-16 |
Edition | 1.0 |
ICS | 07.120 |
Stability date | 2027 |
ISBN number | 9782832289877 |
Pages | 71 |
File size | 4.94 MB |
-
Build resilient infrastructure, promote inclusive and sustainable industrialization and foster innovation