IEC 60092-353 Redline version
IEC 60092-353:2024 RLV
Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
IEC 60092-353:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60092-353:2024 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations. Cables designed to maintain circuit integrity during a fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Updated references to IEC 60092-350 for general construction and test methods and IEC 60092-360 for insulating and sheathing materials.
b) Added subclause 5.10: Construction for special applications.
c) Added Table 9: Additional test for cables for installation between areas with and without explosive atmospheres.
d) Deleted the test requirement IEC 60331-21 from Table 7.
e) Deleted the former Annex A (Alternative enhanced insulation thickness for 0,6/1 kV).
IEC 60092-353:2024 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations. Cables designed to maintain circuit integrity during a fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Updated references to IEC 60092-350 for general construction and test methods and IEC 60092-360 for insulating and sheathing materials.
b) Added subclause 5.10: Construction for special applications.
c) Added Table 9: Additional test for cables for installation between areas with and without explosive atmospheres.
d) Deleted the test requirement IEC 60331-21 from Table 7.
e) Deleted the former Annex A (Alternative enhanced insulation thickness for 0,6/1 kV).
CHF 255.-
Technical committee
TC 18/SC 18A Electric cables for ships and mobile and fixed offshore unitsPublication type | International Standard |
Publication date | 2024-06-06 |
Edition | 5.0 |
ICS | 29.060.20 47.020.60 |
Stability date | 2027 |
ISBN number | 9782832291184 |
Pages | 43 |
File size | 1.02 MB |
-
Build resilient infrastructure, promote inclusive and sustainable industrialization and foster innovation