IEC 61000-4-8:2009 RLV 
Redline version

Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

English/French
CHF 

Do you need a multi-user copy?

English/French
CHF 

Preview

Abstract

IEC 61000-4-8:2009 RLV contains the International Standard and its Redline version. The Redline version provides you with a quick and easy way to compare all the changes between this standard and its previous edition. The Redline version is not an official IEC Standard, only the current version of the standard is to be considered the official document.
IEC 61000-4-8:2009 relates to the immunity requirements of equipment, only under operational conditions, to magnetic disturbances at power frequencies 50 Hz and 60 Hz related to:
- residential and commercial locations;
- industrial installations and power plants;
- medium voltage and high voltage sub-stations.
The applicability of IEC 61000-4-8:2009 to equipment installed in different locations is determined by the presence of the phenomenon, as specified in Clause 4. This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. Other IEC standards dealing with conducted disturbances cover these aspects. The object of IEC 61000-4-8:2009 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment for household, commercial and industrial applications when subjected to magnetic fields at power frequency (continuous and short duration field). IEC 61000-4-8:2009 defines:
- recommended test levels;
- test equipment;
- test set-up;
- test procedure.
This second edition cancels and replaces the first edition published in 1993 and its Amendment 1 (2000). It forms a technical revision. This edition includes the following significant technical changes with respect to the previous edition: the scope is extended in order to cover 60 Hz. Characteristics, performance and verification of the test generator and related inductive coils are revised. Modifications are also introduced in the test set-up (GRP) and test procedure. IEC 61000-4-8:2009 has the status of a basic EMC publication in accordance with IEC Guide 107.

Additional information

Publication typeInternational Standard
Publication date2009-09-03
Edition2.0
Available language(s)English/French
TC/SCTC 77/SC 77A - EMC - Low frequency phenomenarss
ICS33.100.20 - Immunity
Stability date  2027
Pages141
File size2507 KB

The following test report forms are related:



Share your publications

Learn how to share your publications with your colleagues, using networking options.

Payment information

Our prices are in Swiss francs (CHF). We accept all major credit cards (American Express, Mastercard and Visa, JCB and CUP), PayPal and bank transfers as form of payment.


Keep in touch

Keep up to date with new publication releases and announcements with our free IEC Just Published email newsletter.

Contact customer services

Please send your enquiry by email or call us on +41 22 919 02 11 between 09:00 – 16:00 CET Monday to Friday.